Our air-wash "Climatizer" system does not use emersion elements or a boiling pot, so there's no need for float switches and no guess work when it comes to humidity levels.
The PID (Proportional-Integral-Derivative) Controls provide a gentle heat and humidity curve preventing over-shoot so you're not pouring water down the drain. The control is mounted conveniently in the door at eye level and has large LED displays for time, temperature and humidity so your operators can keep track of every step of the proofing operation.
LBC Proofers are available in single door, double door and triple wide models in depths starting from 30" all the way up to 120" deep. All models assemble using a cam-lock design, minimizing installation time.
 |
Full Insulated Cam Lock Construction |
 |
Single Door, Double Door, Triple Door |
 |
Air Wash Humidity System |
 |
PID Computer Controls |
 |
208/240 VAC Single or 3-phase |
 |
One-Year Parts and Labor Warranty |
| BakerSeries®
Roll-In Rack, Single Door Proofer |
|
|
|
| |
| Model
# |
LRP-1 |
| Shipping Wt./Class |
1075+/70 |
Product
Spec Sheet
Rack Sizing Guide
Electrical
Available in 208V or 240V; 1 or 3-phase
kW: see spec sheets
|
|
|
| BakerSeries®
Roll-In Rack, Two Door Proofer |
|
|
|
| |
| Model
# |
LRP-2 |
| Shipping Wt./Class |
1160+/70 |
Product
Spec Sheet
Rack Sizing Guide
Electrical
Available in 208V or 240V; 1 or 3-phase
kW: see spec sheets
|
|
|
| BakerSeries®
Roll-In Rack, Triple Wide Two Door Proofer |
 |
|
| |
| Model
# |
LRP-3 |
| Shipping Wt./Class |
1375+/70 |
Product
Spec Sheet
Rack Sizing Guide
Electrical
Available in 208V or 240V; 1 or 3-phase
kW: see spec sheets
|
|
|